Please use this identifier to cite or link to this item: http://repo.lib.jfn.ac.lk/ujrr/handle/123456789/1792
Title: Shanking Table Tests On Pp-Band Retrofitting Of 1/4 Scale Unreinforced Stone Masonry Models
Authors: Sathiparan, N.
Sakurai, K.
Numada, M.
Meguro, K.
Keywords: stone masonry;polypropylene band
Issue Date:  201
Citation: Sathiparan, N., SAKURAI, K., NUMADA, M., & MEGURO, K. (2011). SHANKING TABLE TESTS ON PP-BAND RETROFITTING OF 1/4 SCALE UNREINFORCED STONE MASONRY MODELS. Bulletin of ERS, (44), 139-148.
Abstract: This paper introduces a technically feasible and economically affordable PP-band (polypropylene bands) retrofitting for low earthquake resistant masonry structures in developing countries. Results of the material tests and shaking table tests on building models show that the PP-band retrofitting technique can enhance safety of both existing and new masonry buildings even in worst case scenario of earthquake ground motion like JMA7 seismic intensity. Therefore, proposed method can be one of the optimum solutions for promoting safer building construction in developing countries and contribute earthquake disaster mitigation in the future.
URI: http://repo.lib.jfn.ac.lk/ujrr/handle/123456789/1792