Please use this identifier to cite or link to this item:
http://repo.lib.jfn.ac.lk/ujrr/handle/123456789/1800
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ramya, P. | |
dc.contributor.author | Padmapriya, B. | |
dc.contributor.author | Poornachandra, S. | |
dc.contributor.author | Arumugaraja, M. | |
dc.date.accessioned | 2021-03-08T09:42:29Z | |
dc.date.accessioned | 2022-07-07T05:02:48Z | - |
dc.date.available | 2021-03-08T09:42:29Z | |
dc.date.available | 2022-07-07T05:02:48Z | - |
dc.date.issued | 2019 | |
dc.identifier.issn | 0925-3467 | |
dc.identifier.uri | http://repo.lib.jfn.ac.lk/ujrr/handle/123456789/1800 | - |
dc.description.abstract | Arthritis is an intense or unremitting irritation ailment that influences the joints, connective tissues, muscle, ligaments, and stringy tissue. It is a main cause of inability among individuals more than 50 years old in developed country, also it tends to strike amid the most beneficial long periods of adulthood regularly causing torment and deformation. It offers ascend to tremendous healthcare expenditures and loss of work. With the existing system, there are different size of FSR sensors used for foot pressure analysis. A sole with major pressure points (2 - 9) was designed to analyse the foot pressure but unfortunately, the foot size differs from one person to another person. So, the single sole design setup cannot be used for all the persons. In the proposed method, a sensor array designed with single layer carbon loaded polyethylene film was designed and each sensor with sides 21 mm x 21 mm to form the 7x3 array pattern of foot pressure pad. By using the array foot pressure pad, we can analyse the pressure points throughout the pad. Each of the sensors in the array is having the gap of 5mm. The output analog signal acquired and this electrical signal may result in pre-emptive of the knee problem. | en_US |
dc.language.iso | en | en_US |
dc.publisher | University of Jaffna | en_US |
dc.subject | Piezo resistive | en_US |
dc.subject | Foot pressure monitoring | en_US |
dc.subject | velostat | en_US |
dc.subject | pressure pad | en_US |
dc.title | Single Layer Carbon Loaded Polyethylene Film for Foot Pressure Monitoring | en_US |
dc.type | Article | en_US |
Appears in Collections: | AMCEHA 2019 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
[02] Proceedings AMCEHA-2019-Page13.pdf | 578.91 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.